Inductive sensor PL3-F25-N4-K

Part number: PL3-F25-N4-K

  • For installation in housing
  • PL3... with valve and screen connection
  • Valve LEDs disconnectable (wire jumper)
  • ATEX & IECEX certifications
  • Specification

    General specifications
    Switching function2 x normally closed (NC)
    Output typeNAMUR
    Rated operating distance3 mm
    Installationflush mountable
    Assured operating distance0 ... 2.43 mm
    Actual operating distance2.7 ... 3.3 mm
    Reduction factor rAl 0.52
    Reduction factor rCu 0.43
    Reduction factor r304 0.86
    Reduction factor rSt37 1
    Reduction factor rBrass 0.54
    Output type2-wire
    Nominal ratings
    Nominal voltage8.2 V (Ri approx. 1 kΩ)
    Operating voltage5 ... 25 V
    Switching frequency0 ... 100 Hz
    Hysteresistyp. 5 %
    Reverse polarity protectionreverse polarity protected
    Short-circuit protectionyes
    Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
    Current consumption
    Measuring plate not detected≥ 3 mA at nominal voltage
    Measuring plate detected≤ 1 mA at nominal voltage
    Time delay before availability≤ 1 ms
    Switching state indicatorLED, yellow
    Valve status indicatorLED, yellow
    can be switched off by of DB1
    Functional safety related parameters
    MTTFd834 a
    Mission Time (TM)20 a
    Diagnostic Coverage (DC)0 %
    Compliance with standards and directives
    Standard conformity
    NAMUREN 60947-5-6:2000
    IEC 60947-5-6:1999
    Electromagnetic compatibilityNE 21:2007
    StandardsEN 60947-5-2:2007
    EN 60947-5-2/A1:2012
    IEC 60947-5-2:2007
    IEC 60947-5-2 AMD 1:2012
    Approvals and certificates
    IECEx approval
    Equipment protection level GaIECEx TUN 17.0021X
    Equipment protection level GbIECEx TUN 17.0021X
    Equipment protection level MbIECEx TUN 17.0021X
    ATEX approval
    Equipment protection level GaTÜV 99 ATEX 1479 X
    Equipment protection level GbTÜV 99 ATEX 1479 X
    Equipment protection level Gc (ic)PF13CERT2895 X
    CCC approval
    Hazardous Location2020322315002262
    NEPSI approval
    NEPSI certificateGYJ19.1410X
    Ambient conditions
    Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
    Storage temperature-40 ... 100 °C (-40 ... 212 °F)
    Mechanical specifications
    Connection (system side)Cage tension spring terminals
    Core cross section (system side)up to 2.5 mm2
    Connection (valve side)Cage tension spring terminals
    Core cross section (valve side)up to 2.5 mm2
    Housing materialPBT
    Sensing facePBT
    Mass91 g
    Tightening torque, fastening screws0.3 Nm
    General information
    Use in the hazardous areasee instruction manuals
    ECLASS 13.027220501
    ECLASS 12.027220501
    ECLASS 11.027220501
    ECLASS 10.0.127220501
    ECLASS 9.027220501
    ECLASS 8.027220501
    ECLASS 5.127220501
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550