Inductive sensor NJ20+U1+E2-Y287109

Part number: NJ20+U1+E2-Y287109

  • Comfort series
  • 20 mm flush
  • Specification

    General specifications
    Switching functionNormally open (NO)
    Output typePNP
    Rated operating distance20 mm
    Installationflush
    Output polarityDC
    Assured operating distance0 ... 16.2 mm
    Actual operating distance18 ... 22 mm typ. 20 mm
    Reduction factor rAl 0.35
    Reduction factor rCu 0.35
    Reduction factor r304 0.8
    Output type3-wire
    Nominal ratings
    Operating voltage10 ... 30 V
    Switching frequency0 ... 150 Hz
    Hysteresis1 ... 10 typ. 5 %
    Reverse polarity protectionreverse polarity protected
    Short-circuit protectionpulsing
    Voltage drop≤ 2.8 V
    Voltage drop at IL
    Voltage drop IL = 1 mA, switching element on0.5 ... 2.3 V typ. 0.9 V
    Voltage drop IL = 10 mA, switching element on0.8 ... 2.2 V typ. 1.4 V
    Voltage drop IL = 20 mA, switching element on0.9 ... 2.3 V typ. 1.5 V
    Voltage drop IL = 50 mA, switching element on0.9 ... 2.5 V typ. 1.6 V
    Voltage drop IL = 100 mA, switching element on1 ... 2.6 V typ. 1.8 V
    Voltage drop IL = 200 mA, switching element on1.2 ... 2.8 V typ. 2 V
    Operating current0 ... 200 mA
    Off-state current0 ... 0.5 mA typ. 0.01 mA
    Off-state current TU =40 °C, switching element off≤ 100 µA
    No-load supply current≤ 10 mA
    Time delay before availability≤ 50 ms
    Operating voltage indicatorLED, green
    Switching state indicatorLED, yellow
    Functional safety related parameters
    MTTFd819 a
    Mission Time (TM)20 a
    Diagnostic Coverage (DC)0 %
    Compliance with standards and directives
    Standard conformity
    StandardsEN 60947-5-2:2007
    IEC 60947-5-2:2007
    Approvals and certificates
    UL approvalcULus Listed, General Purpose
    CCC approvalCCC approval / marking not required for products rated ≤36 V
    Ambient conditions
    Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
    Storage temperature-25 ... 85 °C (-13 ... 185 °F)
    Mechanical specifications
    Connection typescrew terminals
    Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
    tightening torque 1.2 Nm + 10 %
    Core cross sectionup to 2.5 mm2
    Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
    Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
    Cable gland
    NoteSealing ring:
    Hole diameter 7 / 10.5 / 13 / 16 mm
    The dimension of the connection cable must correspond to the hole selected on the sealing ring.
    Housing materialPBT with Viton seals and PVDF screwed connection
    Sensing facePBT
    Degree of protectionIP68
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550