Inductive sensor NCB3-14GM65-E2-D-V1

Part number: NCB3-14GM65-E2-D-V1

  • 3 mm flush
  • Operating pressure 500 bar, peak pressure 800 bar
  • For applications in hydraulic cylinder
  • Specification

    General specifications
    Switching functionNormally open (NO)
    Output typePNP
    Rated operating distance3 mm
    Installationflush
    Output polarityDC
    Reduction factor rAl 0
    Reduction factor rCu 0
    Reduction factor r304 0.85
    Reduction factor rSt37 1
    Reduction factor rBrass 0.15
    Output type3-wire
    Nominal ratings
    Operating voltage10 ... 30 V DC
    Switching frequency0 ... 500 Hz
    Hysteresistyp. 10 %
    Reverse polarity protectionreverse polarity protected
    Short-circuit protectionpulsing
    Voltage drop≤ 2 V
    Repeat accuracy0.1 mm
    Temperature drift± 15% max.
    Operating current≤ 200 mA
    No-load supply current≤ 10 mA
    Time delay before availability≤ 10 ms
    Limit data
    Operating pressure500 bar (7252 psi)
    Peak pressure800 bar (11603.2 psi)
    Compliance with standards and directives
    Standard conformity
    StandardsEN 60947-5-2:2007
    IEC 60947-5-2:2007
    Approvals and certificates
    UL approvalcULus Listed, General Purpose
    CSA approvalcCSAus Listed, General Purpose
    CCC approvalCCC approval / marking not required for products rated ≤36 V
    Ambient conditions
    Ambient temperature-25 ... 80 °C (-13 ... 176 °F)
    Mechanical specifications
    Connection typeConnector plug M12 x 1 , 4-pin
    Housing materialStainless steel 1.4305 / AISI 303
    Sensing faceCeramic
    Degree of protectionIP68
    Mass73 g
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550