Inductive sensor NCN50-FP-W-P1

Part number: NCN50-FP-W-P1

  • 50 mm non-flush
  • 2-wire AC
  • Specification

    General specifications
    Switching functionNormally open/closed (NO/NC)
    Output typeTwo-wire
    Rated operating distance50 mm
    Installationnon-flush
    Output polarityAC
    Assured operating distance0 ... 40.5 mm
    Reduction factor rAl 0.4
    Reduction factor rCu 0.3
    Reduction factor r304 0.85
    Output type2-wire
    Nominal ratings
    Operating voltage20 ... 253 V AC
    Switching frequency0 ... 20 Hz
    Hysteresistyp. 3 %
    Short-circuit protectionno
    Voltage drop≤ 5 V typ. 4V
    Momentary current
    (20 ms, 0.1 Hz)
    max. 4000 mA
    Operating current5 ... 500 mA
    Off-state current0.3 ... 1 mA typ. 0.7 mA
    Time delay before availability≤ 100 ms
    Operating voltage indicatorLED, green
    Switching state indicatorLED, yellow
    Compliance with standards and directives
    Standard conformity
    StandardsEN IEC 60947-5-2
    Approvals and certificates
    UL approvalcULus Listed, General Purpose
    CSA approvalcCSAus Listed, General Purpose
    CCC approvalCertified by China Compulsory Certification (CCC)
    Ambient conditions
    Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
    Mechanical specifications
    Connection typescrew terminals
    Core cross sectionup to 2.5 mm2
    Housing materialPBT
    Sensing facePBT
    Housing basePBT
    Degree of protectionIP68
    Tightening torque, housing screws1 Nm
    Note1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V
    Safety fuse ≤ 2 A (quick-blow) according to IEC 60127-2 Sheet 1
    Recommendation: after a short circuit, check that the device is functioning correctly.
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550