Inductive sensor NCB4-12GM40-Z4-V1

Part number: NCB4-12GM40-Z4-V1

  • 4 mm flush
  • 2-wire DC
  • Increased operating distance
  • Specification

    General specifications
    Switching functionNormally open (NO)
    Output typeTwo-wire
    Rated operating distance4 mm
    Installationflush
    Output polarityDC
    Assured operating distance0 ... 3.24 mm
    Reduction factor rAl 0.49
    Reduction factor rCu 0.47
    Reduction factor r304 0.76
    Output type2-wire
    Nominal ratings
    Operating voltage3.5 ... 30 V
    Switching frequency0 ... 1000 Hz
    Hysteresistyp. 5 %
    Reverse polarity protectionreverse polarity-conductive
    Short-circuit protectionpulsing
    Voltage drop≤ 3.5 V
    Temperature drift± 15%
    Operating current2 ... 100 mA
    Off-state current0.4 ... 0.6 mA typ. 0.5 mA
    Switching state indicatorLED, yellow
    Stability alarm indicatorLED, red
    Stability control-switch point0,8 sr ... 0,9 sr
    Functional safety related parameters
    MTTFd1883 a
    Mission Time (TM)20 a
    Diagnostic Coverage (DC)0 %
    Compliance with standards and directives
    Standard conformity
    StandardsEN 60947-5-2:2007
    EN 60947-5-2/A1:2012
    IEC 60947-5-2:2007
    IEC 60947-5-2 AMD 1:2012
    Approvals and certificates
    UL approvalcULus Listed, General Purpose
    CSA approvalcCSAus Listed, General Purpose
    CCC approvalCCC approval / marking not required for products rated ≤36 V
    Ambient conditions
    Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
    Storage temperature-40 ... 85 °C (-40 ... 185 °F)
    Mechanical specifications
    Connection typeConnector plug M12 x 1 , 4-pin
    Housing materialbrass, nickel-plated
    Sensing facePBT
    Degree of protectionIP67
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550