Inductive sensor NBB1,5-F41-E2-V3

Part number: NBB1,5-F41-E2-V3

  • 1.5 mm flush
  • 3-wire DC
  • Metal housing
  • Specification

    General specifications
    Switching functionNormally open (NO)
    Output typePNP
    Rated operating distance1.5 mm
    Installationflush
    Output polarityDC
    Assured operating distance0 ... 1.215 mm
    Reduction factor rAl 0.45
    Reduction factor rCu 0.35
    Reduction factor r304 0.75
    Output type3-wire
    Nominal ratings
    Operating voltage10 ... 30 V DC
    Switching frequency0 ... 1500 Hz
    Hysteresistyp. 3 %
    Reverse polarity protectionreverse polarity protected
    Short-circuit protectionpulsing
    Voltage drop≤ 3 V
    Operating current0 ... 100 mA
    Off-state current0 ... 0.5 mA typ.
    No-load supply current≤ 15 mA
    Time delay before availability≤ 20 ms
    Switching state indicatorLED, yellow
    Functional safety related parameters
    MTTFd1528 a
    Mission Time (TM)20 a
    Diagnostic Coverage (DC)0 %
    Compliance with standards and directives
    Standard conformity
    StandardsEN 60947-5-2:2007
    IEC 60947-5-2:2007
    Approvals and certificates
    UL approvalcULus Listed, General Purpose
    CSA approvalcCSAus Listed, General Purpose
    CCC approvalCCC approval / marking not required for products rated ≤36 V
    Ambient conditions
    Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
    Mechanical specifications
    Connection typeConnector plug M8 x 1 , 3-pin
    Housing materialbrass, nickel-plated
    Sensing facePBT
    Degree of protectionIP67
    Mass13.5 g
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550