Inductive sensor NCB20-L2-N0-V1

Part number: NCB20-L2-N0-V1

  • Sensor head bidirectional and rotatable
  • 20 mm flush
  • Quick mounting bracket
  • Usable up to SIL 2 acc. to IEC 61508
  • Specification

    General specifications
    Switching functionNormally closed (NC)
    Output typeNAMUR
    Rated operating distance20 mm
    Installationflush
    Assured operating distance0 ... 16.2 mm
    Actual operating distance18 ... 22 mm
    Reduction factor rAl 0.33
    Reduction factor rCu 0.31
    Reduction factor r304 0.74
    Nominal ratings
    Nominal voltage8.2 V (Ri approx. 1 kΩ)
    Switching frequency0 ... 300 Hz
    Hysteresistyp. 5 %
    Reverse polarity protectionreverse polarity protected
    Short-circuit protectionyes
    Current consumption
    Measuring plate not detected≥ 2.2 mA
    Measuring plate detected≤ 1 mA
    Switching state indicatorLED, yellow
    Functional safety related parameters
    Safety Integrity Level (SIL)SIL 2
    MTTFd1660 a
    Mission Time (TM)20 a
    Diagnostic Coverage (DC)0 %
    Compliance with standards and directives
    Standard conformity
    NAMUREN 60947-5-6:2000
    IEC 60947-5-6:1999
    StandardsEN 60947-5-2:2007
    EN 60947-5-2/A1:2012
    IEC 60947-5-2:2007
    IEC 60947-5-2 AMD 1:2012
    Approvals and certificates
    IECEx approval
    Equipment protection level GaIECEx PTB 11.0021X
    Equipment protection level GbIECEx PTB 11.0021X
    Equipment protection level DaIECEx PTB 11.0021X
    Equipment protection level Dc (tc)IECEx TUR 21.0020X
    Equipment protection level MbIECEx PTB 11.0021X
    ATEX approval
    Equipment protection level GaPTB 00 ATEX 2032 X
    Equipment protection level GbPTB 00 ATEX 2032 X
    Equipment protection level DaPTB 00 ATEX 2032 X
    Equipment protection level Dc (tc)TÜV 20 ATEX 8526 X
    Protection classII
    Rated insulation voltage253 V
    Rated impulse withstand voltage4000 V
    UL approval
    Ordinary LocationE87056
    Hazardous LocationE501628
    Control drawing116-0451
    CCC approval
    Hazardous Location2020322315002302
    NEPSI approval
    NEPSI certificateGYJ16.1394X
    CML approvalon request
    ANZEx19.3001X
    Marine approvalDNVGL TAA00001A5
    Ambient conditions
    Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
    Storage temperature-40 ... 100 °C (-40 ... 212 °F)
    Mechanical specifications
    Connection typeConnector plug
    Housing materialPA
    Sensing facePA
    Degree of protectionIP66 / IP69K
    Connector
    ThreadingM12 x 1
    Number of pins4
    Mass130 g
    General information
    Use in the hazardous areasee instruction manuals
    ECLASS 13.027274001
    ECLASS 12.027274001
    ECLASS 11.027270101
    ECLASS 10.0.127270101
    ECLASS 9.027270101
    ECLASS 8.027270101
    ECLASS 5.127270101
    ETIM 9.0EC002714
    ETIM 8.0EC002714
    ETIM 7.0EC002714
    ETIM 6.0EC002714
    ETIM 5.0EC002714
    UNSPSC 12.139121550